Shop drawings · CSI Division 23

HVAC duct shop drawings for sheet metal contractors.

Ductwork shop drawings for sheet metal and mechanical contractors, with every run sized and set at its elevation, fittings and dampers placed, and hangers and access doors located.

  • Ductwork layout plans
  • Sections
  • Fittings and accessories

What you receive

A drawing set ready for your submittal.

Drafted in AutoCAD and Revit, with anything the contract drawings leave open listed for your RFIs.

  • 01

    PDF set for submittal

  • 02

    Native DWG or RVT files

  • 03

    Imperial or metric units

Drawing set

What the set includes.

The sheets in a typical set of HVAC duct shop drawings. The exact list follows your contract drawings and specification section.

  • Ductwork layout plansSupply, return and exhaust duct, with sizes, bottom-of-duct elevations and pressure class.
  • SectionsDuct through tight ceiling spaces, shafts and around structure.
  • Fittings and accessoriesElbows, transitions, takeoffs, dampers, access doors and flexible connections.
  • Equipment connectionsAir handlers, rooftop units, fans and terminal units, with their connections.
  • Hanger layoutsHanger and support locations.
  • Duct quantitiesDuct by size and gauge, for ordering and fabrication planning.

Method

How we prepare HVAC duct shop drawings.

01

Duct construction follows the pressure class and gauge the specification sets.

02

Fire and smoke dampers are placed where duct crosses rated walls and floors on the life safety plans.

03

Routing is coordinated with structure, sprinklers, plumbing and lights, and clashes are listed as questions.

04

Access doors are located at every damper and device that needs service.

Standards

The references your reviewer expects.

We draft to the standards your contract drawings and specification cite. These are the ones we see most often for this trade.

SMACNA HVAC Duct Construction Standards, Metal and Flexible

Duct construction, gauges, reinforcement and hangers.

NFPA 90A

Fire dampers and duct requirements for air-conditioning systems.

SMACNA Seismic Restraint Manual

Duct bracing, where seismic restraint is required.

Deliverables

What every set includes.

  • PDF drawing set, ready for your submittal
  • Native files: DWG from AutoCAD or RVT from Revit
  • A list of open questions and conflicts, for you to raise as RFIs
  • Revisions to the reviewer's comments, recorded in the title block
  • Imperial or metric units, to match the contract drawings
  • Drafted in AutoCAD and Revit

Who it is for

  • Sheet metal contractors
  • HVAC and mechanical contractors
  • Design-build MEP firms
  • General contractors

Questions contractors ask us

Do you show bottom-of-duct elevations?

Yes. Every run carries its size and bottom-of-duct elevation, so the field can hang it and other trades can plan around it.

Do you place fire and smoke dampers?

Yes. Dampers are placed where duct crosses rated walls and floors on the life safety plans, with access doors for service.

Do you estimate HVAC too?

Yes. Our HVAC and mechanical estimating measures equipment, ductwork and piping from the same drawings.

Are the shop drawings stamped?

Shop drawings are submittals: the architect or engineer of record reviews and approves them. If your project needs a professional engineer's stamp, for example on delegated design, tell us at the quote stage and we will confirm what can be arranged for that project.

How are shop drawings priced?

We review the contract drawings and the specification section, then confirm the fee and the delivery date before any drafting starts.

HVAC Duct shop drawings

Submittal due soon? Send the contract set.

Send the contract drawings, the specification section and the submittal date, and we will quote the HVAC duct shop drawings.